Oregon Approves PGE Schedule 96

Key Facts
  • Load threshold: 20 MW
  • Minimum contract: 10 years (up to 30 years for 220 MW+ loads)
  • Distribution cost: 100% paid by the customer
  • Size surcharge: 1 cent/kWh on projects over 100 MW
  • Effective: June 10, 2026

The Oregon Public Utility Commission has approved Schedule 96, a dedicated rate class that requires data centers and other large electricity users above 20 MW in Portland General Electric’s territory to sign long-term contracts and pay the full cost of the grid upgrades they trigger. The commission adopted the framework in Order No. 26-154 (docket UM 2377) on May 7, 2026, and the tariff took effect on June 10, 2026. It is the first major implementation of Oregon’s 2025 POWER Act and is built to stop residential and small-business customers from subsidizing the surging demand of hyperscale and AI computing campuses.

What Actually Changed

Before Schedule 96, large new loads connected under PGE’s general commercial and industrial schedules, which spread distribution and generation upgrade costs across the whole customer base. Under the new rule, any customer with demand above 20 MW must take service on Schedule 96, commit to a minimum 10-year contract, and cover 100% of the distribution system upgrades needed to serve them. The largest customers face longer commitments: loads of 220 MW or more must sign contracts running up to 30 years. Demand charges are set at 90% of each customer’s contracted capacity, so a data center pays for the headroom it reserves whether or not it draws it, and projects above 100 MW pay an additional 1 cent per kilowatt-hour size-based surcharge, as reported by Utility Dive’s review of the order.

The commission paired the tariff with a “peak growth modifier” that allocates a larger share of growth-driven transmission and generation costs to the customer classes adding the most demand. Schedule 96 also ties interconnection approval to PGE’s clean-energy and emissions obligations: a large-load applicant must show its growth can be served without pushing the utility off its decarbonization targets.

What Didn’t Change

Schedule 96 does not cap how much load a data center can request, and it does not block new campuses from connecting. Existing large customers already under contract are not retroactively moved onto the new class. Residential and small commercial rate designs are untouched — the point of the order is to wall off large-load cost responsibility, not to restructure everyone else’s bills directly.

Critical Perspective

The Oregon PUC’s Schedule 96 mandates that data centers over 20 MW fund their own distribution upgrades, yet this policy fails to account for the intricate interplay between distributed energy resources (DERs) and grid stability as detailed in IEEE standards like IEEE 2988. According to Watt-Logic research, the SVC market was valued at $643.6 million in 2014 and is estimated to reach $807.7 million by 2020, indicating a growing need for such technologies to manage flicker and ensure grid stability. However, Schedule 96 does not require data centers to invest in advanced VAR compensation systems that could mitigate voltage instability issues, which are critical at large scale installations. This oversight risks exacerbating transmission constraints and potentially leading to higher overall distribution costs as more data centers come online without adequate support infrastructure. The question is, how will these large-scale data center projects ensure grid stability and avoid becoming a financial burden on the broader utility system if they do not invest in necessary VAR compensation systems?

Why It Matters

Oregon is one of the fastest-growing data center markets in the West, and PGE’s queue of large-load requests has climbed into the gigawatts. By forcing customers above 20 MW to fund their own interconnection and reserve 90% of contracted capacity, the commission converts an open-ended subsidy risk into a binding financial commitment. As of May 2026, 23 states had approved at least one large-load tariff; Oregon’s version is among the most aggressive on contract length and cost allocation, giving other state commissions a template as AI demand collides with grid-expansion costs.

Enforcement Reality

Because Schedule 96 is a filed tariff approved by the commission, PGE must apply it to every qualifying customer — it is not a voluntary program. Enforcement runs through the contract: a data center that wants to interconnect signs the 10-year (or longer) agreement and accepts the minimum-demand provisions before energization, and the commission keeps authority over disputes through the UM 2377 docket. The open question is whether the 1 cent per kilowatt-hour surcharge and the 90% demand floor are high enough to deter speculative interconnection requests, or whether well-capitalized hyperscalers absorb them as a cost of doing business in Oregon.